3:连接入口圆顶阀上与插板门之间的短节时,需要保证圆顶阀的圆顶四周无杂物。4:所有设备安装后,(单个电场)做系统压力实验。用压力为0.7MPa的压缩空气做气密试验,压降在30分钟内小于0.1MPa,用肥皂水检查泄**,保证管道无泄**。5:金属波纹膨胀节(补偿器)在安装后需要将(膨胀节)运输用的固定...
气力输灰系统由电除尘器飞灰处理系统、库顶卸料及排气系统、灰库气化风系统、库底卸料系统、控制用气及布袋脉冲清洗用气系统、输送用空压机系统及空气净化系统、控制系统组成。通过压缩空气作为气力输灰的动力源,由设置在仓泵上的密闭管道,使粉煤灰被输送到灰库,再通过库底卸料器、散装机、双轴搅拌机向外排灰,实现无污染排灰。
LD型浓相气力输送泵在本系统中主要用于粉煤灰的输送,它自动化程度高,利用PLC控制整个输送过程实行全自动控制。主要由进料装置、气动出料阀、泵体、气化装置、管路系统及阀门组成。仓泵过程分为四个阶段: 单个给料点的输送用浓相仓式泵,多个给料点的输送用小型AV泵、密相泵,小型AV泵、密相泵可以串联输送。福建仓式泵零售

(1) 检查冷却水是否充足,供气阀门应处于“关闭”位置。
Check if there is enough cooling water, and the air supply valve shall be in “Close” position.
(2) 检查电源电压是否符合机组要求。
Check the power supply voltage is correct.
(3) ***机组周围的杂物,以确保操作安全。
Clean all rubbish from the machine and around to ensure the safety operation of the machine.
5.冷冻干燥机的检查 Check the freezer dryer
(1) 检查干燥机内、外部各部位是否紧固,不准任何联接有松动现象。
Check if all components of freezer dryer inside and outside is fastened. It is forbidden to have any loosening of the interconnection.
(2) 检查电源电压、来气压力、进口温度、处理风量等工况条件是否与明等。
Check if the power supply voltage, air supply pressure, inlet temperature and treatment air quantity etc. working condition are agreed with what in the nameplate. 5立方仓式泵应用结构简单、性能可靠、维护工作量少。 AV泵、密相泵运行过程 。

2:泵启动, 泵内装料完成,圆顶阀关闭,但不输送。1.圆顶阀密封压力信号不对或限位开关不动作1检查、调整错误的密封压力反馈信号的相关条件。
若有故障则更换限位开关。 2.圆顶阀未关严, 外物卡住圆顶阀或轴2.切断气路和电路, 从底部弯头拆出管子做清理, 清理容器。
拆去汽缸, 手动操作,检查限位开关的动作。 3.喷吹阀不工作或输送空气管道的手动阀门关闭.3.检查阀的供气。若供气良好, 则修理或更换阀门。若没有供气, 检查喷吹电磁阀的动作或限位开关
2:热态调试。
l 调试准备
完成冷态调试后,待灰斗带料时即可准备热态调试。
l 调试过程中的步骤和相关监测
A:将插板门逐台打开,落料时间有小逐渐增加到可以落满泵的时间。
B:对有关压力、时间参数进行调试,使系统可以做到满泵运行。
C:调试中,对落灰情况要进行定时检查、确认。
D:对系统设备中所有设备相关相同部位(落灰短节、排气管)的温度进行监测,确认运行状态。
E:对节流孔板的气量进行调节,使耗气量接近或符合设计要求。(注:在灰质偏离设计参数时,该项将会有较大的误差)。
F:通过每小时循环次数、单次输送的重量(或体积)计算每小时的系统出力。并与设计处理比较。
九:AV泵运行注意事项
1、巡测各个电场的灰斗出口短节的温度。
在正常运行中,一电场落灰短节温度80—100℃,二电场50—70℃,三电场30—50℃。
检测此处温度,用来检查落灰情况和灰斗存灰情况。
如果同一电场的短节温度差异较大,就有可能存在各个灰斗落灰不均匀或某个灰斗落灰较差的现象。需要调整电除尘器的负荷分配或对落灰时间、循环间隔时间做相应调整,使落灰正常,保证运行处于良性循环。
在现场调试中,要求现场在每次运行开始阶段,每4小时对所有的短节温度进行一次监测。 在开始修理或对系统上任何部件或本手册中所列部件的任何其它工作之前,。

(1) 检查进气阀、供气阀是否处于“关闭”状态。
Check the intake valve, air supply valve is in “Close” position.
(2) 检查电源电压的波动范围,不得超过额定电压的±5%
Check the fluctuation of the power supply voltage, which shall be within ±5%.
(3) 确认贮气罐及系统各处节阀处于正常位置。
Confirm all valves for air tank and system are in normal position.
(4) 清理机组周围杂物,以确保机组运行安全。
Clean all rubbish from the machine and around to ensure the safety operation of the machine.
二、系统的启动 Starting up of the system
1.系统的启动顺序:Starting sequence of the system:
空气压缩机→干燥机→仓顶除尘器→输灰仓泵→空气电加热器→搅拌机
Air compressor→air dryer→silo top dust cleaner →ash conveying pump→electric air heater → mixer
2.空气压缩机的启动 Starting up the air compressor
(1) 接通水路,冷却水正常供水。
Connect to the water supply, keep the cooling water supply normally.
(2) 按下“启动”按钮,压缩机开始启动。
Press down the “Start” button to start up the compressor. AV泵、密相泵采用底部出料管。湖南布袋除尘仓式泵
②当同一组所有灰斗中任何一个的料位计被覆盖,系统触发。福建仓式泵零售
在运行中如出现问题因及时处理。
启动前的检查 Inspection before starting
1.仓泵的检查 Check the conveying pump
(1) 清理仓泵泵体和周围的杂物、积灰。
Clean all the impurities and accumulated dust from conveying pump vessel and around.
(2) 检查就地控制箱操作按钮是否处于“自动”状态。各气动阀门按钮是否处于“关”状态。
Check if the press button of the local cabinet is in “Auto” position. Check if the press button of all pneumatic valves is in “Close” position.
(3) 检查各管路连接处是否有漏气现象。
Check all pipe connections if there is any air leakage.
(4) 检查各仪表指示是否正常。
Check if all instrument is in normal condition.
(5) 检查空气滤气器内是否有积水或积尘,油雾器内是否油位合格。
Check if there is any water or dust accumulated inside the air filter, and check if the oil level of the lubricator is ok.
福建仓式泵零售江苏恒博气力输送设备制造有限公司致力于机械及行业设备,是一家生产型的公司。公司业务涵盖气力输送设备,正压气力输送设备,定量等,价格合理,品质有保证。公司从事机械及行业设备多年,有着创新的设计、强大的技术,还有一批**的专业化的队伍,确保为客户提供良好的产品及服务。在社会各界的鼎力支持下,持续创新,不断铸造***服务体验,为客户成功提供坚实有力的支持。
3:连接入口圆顶阀上与插板门之间的短节时,需要保证圆顶阀的圆顶四周无杂物。4:所有设备安装后,(单个电场)做系统压力实验。用压力为0.7MPa的压缩空气做气密试验,压降在30分钟内小于0.1MPa,用肥皂水检查泄**,保证管道无泄**。5:金属波纹膨胀节(补偿器)在安装后需要将(膨胀节)运输用的固定...
开封密相气力输送系统
2025-12-28
河南粉体气力输送工程
2025-12-28
河南仓泵气力输送装置
2025-12-28
黑龙江圆顶阀价格
2025-12-28
唐山粉体气力输送机
2025-12-28
唐山仓泵气力输送系统报价
2025-12-28
重庆下引仓式泵
2025-12-28
辽宁仓式泵参数
2025-12-28
河南粉体气力输送设备
2025-12-28